{"product_id":"panthaire-wine-cellar-cooling-systems-apex-5000","title":"Panthaire Wine Cellar Cooling Systems APEX 5000","description":"\u003ch2 data-start=\"600\" data-end=\"660\"\u003eQuiet, Fully Ducted Cooling for Mid-to-Large Wine Cellars\u003c\/h2\u003e\n\u003cp data-start=\"662\" data-end=\"1051\"\u003eThe \u003cstrong data-start=\"666\" data-end=\"690\"\u003ePantheaire APEX 5000\u003c\/strong\u003e is a fully ducted wine cellar cooling system engineered for collectors who require \u003cstrong data-start=\"774\" data-end=\"855\"\u003equiet operation, precise temperature control, and long-term wine preservation\u003c\/strong\u003e. Designed for \u003cstrong data-start=\"870\" data-end=\"928\"\u003eproperly insulated wine cellars up to 1,200 cubic feet\u003c\/strong\u003e, this system delivers professional-grade performance while keeping all mechanical noise and heat outside the cellar space.\u003c\/p\u003e\n\u003cp data-start=\"1053\" data-end=\"1264\"\u003eIdeal for residential wine rooms and light commercial installations, the APEX 5000 offers a refined solution for protecting valuable wine collections without compromising comfort, aesthetics, or aging integrity.\u003c\/p\u003e\n\u003ch2 data-start=\"1271\" data-end=\"1327\"\u003eWhy Choose a Fully Ducted Wine Cellar Cooling System?\u003c\/h2\u003e\n\u003cp data-start=\"1329\" data-end=\"1620\"\u003eUnlike self-contained cooling units that sit partially inside the cellar, the APEX 5000 uses a \u003cstrong data-start=\"1424\" data-end=\"1468\"\u003efully ducted, remote installation design\u003c\/strong\u003e. This allows the system to be installed in a mechanical room or adjacent space while conditioned air is delivered discreetly through insulated ducting.\u003c\/p\u003e\n\u003cp data-start=\"1622\" data-end=\"1662\"\u003e\u003cstrong data-start=\"1622\" data-end=\"1662\"\u003eBenefits of a ducted system include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1663\" data-end=\"1819\"\u003e\n\u003cli data-start=\"1663\" data-end=\"1695\"\u003eNear-silent cellar operation\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1739\"\u003eReduced vibration for proper wine aging\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1776\"\u003eGreater installation flexibility\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1819\"\u003eClean, uninterrupted cellar aesthetics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1821\" data-end=\"1976\"\u003eFor collectors prioritizing quiet performance and design flexibility, ducted cooling systems represent the highest standard in wine cellar climate control.\u003c\/p\u003e\n\u003ch2 data-start=\"1983\" data-end=\"2026\"\u003eWho the Pantheaire APEX 5000 Is Best For\u003c\/h2\u003e\n\u003cp\u003eThe APEX 5000 is an excellent choice for:\u003c\/p\u003e\n\u003cul data-start=\"2071\" data-end=\"2392\"\u003e\n\u003cli data-start=\"2071\" data-end=\"2133\"\u003eWine cellars \u003cstrong data-start=\"2086\" data-end=\"2109\"\u003eup to 1,200 cu. ft.\u003c\/strong\u003e with \u003cstrong data-start=\"2115\" data-end=\"2133\"\u003eR20 insulation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2134\" data-end=\"2198\"\u003eResidential collectors with large or valuable wine collections\u003c\/li\u003e\n\u003cli data-start=\"2199\" data-end=\"2256\"\u003eCellars where \u003cstrong data-start=\"2215\" data-end=\"2256\"\u003enoise and vibration must be minimized\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2257\" data-end=\"2318\"\u003eCustom cellar builds with available remote mechanical space\u003c\/li\u003e\n\u003cli data-start=\"2319\" data-end=\"2392\"\u003eProjects requiring ducted airflow rather than through-wall installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong data-start=\"2394\" data-end=\"2413\"\u003eNot recommended\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cul data-start=\"2419\" data-end=\"2600\"\u003e\n\u003cli data-start=\"2419\" data-end=\"2458\"\u003eGlass-heavy or poorly insulated rooms\u003c\/li\u003e\n\u003cli data-start=\"2459\" data-end=\"2528\"\u003eMixed-use living spaces without professional heat-load calculations\u003c\/li\u003e\n\u003cli data-start=\"2529\" data-end=\"2600\"\u003eCellars exceeding recommended size without additional cooling support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2607\" data-end=\"2645\"\u003eKey Features \u0026amp; Performance Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-start=\"2647\" data-end=\"2699\"\u003e\n\u003cstrong\u003ePrecision Cooling for Properly Insulated Cellars: \u003c\/strong\u003eWith a cooling capacity of \u003cstrong data-start=\"2727\" data-end=\"2742\"\u003e4,462 BTU\/h\u003c\/strong\u003e, the APEX 5000 is designed to maintain stable cellar temperatures in environments built specifically for wine storage.\u003c\/li\u003e\n\u003cli data-start=\"2863\" data-end=\"2900\"\u003e\n\u003cstrong\u003eFully Ducted, Remote Installation: \u003c\/strong\u003eBy locating the system outside the cellar, heat and operational noise are removed from the wine room, preserving both comfort and ambiance.\u003c\/li\u003e\n\u003cli data-start=\"3042\" data-end=\"3077\"\u003e\n\u003cstrong\u003eLow-Vibration Compressor Design: \u003c\/strong\u003eReduced vibration helps prevent sediment disturbance, supporting proper long-term bottle aging.\u003c\/li\u003e\n\u003cli data-start=\"3175\" data-end=\"3206\"\u003e\n\u003cstrong\u003eDigital Temperature Control: \u003c\/strong\u003eMaintains consistent temperatures within the ideal wine storage range, helping protect both red and white collections.\u003c\/li\u003e\n\u003cli data-start=\"3327\" data-end=\"3360\"\u003e\n\u003cstrong\u003eBalanced Airflow Distribution: \u003c\/strong\u003eMultiple fan speeds deliver even air circulation, minimizing hot or cold zones throughout the cellar.\u003c\/li\u003e\n\u003cli data-start=\"3464\" data-end=\"3499\"\u003e\n\u003cstrong\u003eBuilt for Long-Term Reliability: \u003c\/strong\u003eCommercial-grade components ensure dependable performance in residential and light commercial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3614\" data-end=\"3632\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"3634\" data-end=\"3812\"\u003e\n\u003cli data-start=\"3634\" data-end=\"3671\"\u003ePantheaire APEX 5000 cooling unit\u003c\/li\u003e\n\u003cli data-start=\"3672\" data-end=\"3706\"\u003eDigital temperature controller\u003c\/li\u003e\n\u003cli data-start=\"3707\" data-end=\"3738\"\u003eIntegrated drain connection\u003c\/li\u003e\n\u003cli data-start=\"3739\" data-end=\"3769\"\u003eInstallation summary sheet\u003c\/li\u003e\n\u003cli data-start=\"3770\" data-end=\"3812\"\u003eUser guide and technical documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"3819\" data-end=\"3869\"\u003eTechnical Specifications – Pantheaire APEX 5000\u003c\/h2\u003e\n\u003ch3 data-start=\"3871\" data-end=\"3894\"\u003eCooling Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"3895\" data-end=\"4046\"\u003e\n\u003cstrong data-start=\"3895\" data-end=\"3916\"\u003eCooling Capacity:\u003c\/strong\u003e 4,462 BTU\/h\u003cbr data-start=\"3928\" data-end=\"3931\"\u003e\u003cstrong data-start=\"3931\" data-end=\"3959\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3895\" data-end=\"4046\"\u003e\n\u003cstrong data-start=\"3931\" data-end=\"3959\"\u003eRecommended Cellar Size:\u003c\/strong\u003e Up to 1,200 cu. ft. (with R20 insulation)\u003cbr data-start=\"4001\" data-end=\"4004\"\u003e\u003cstrong data-start=\"4004\" data-end=\"4026\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3895\" data-end=\"4046\"\u003e\n\u003cstrong data-start=\"4004\" data-end=\"4026\"\u003eTemperature Range:\u003c\/strong\u003e 50–70°F (10–25°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4048\" data-end=\"4075\"\u003eElectrical Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4076\" data-end=\"4182\"\u003e\n\u003cstrong data-start=\"4076\" data-end=\"4093\"\u003ePower Supply:\u003c\/strong\u003e 115V \/ 60Hz\u003cbr data-start=\"4105\" data-end=\"4108\"\u003e\u003cstrong data-start=\"4108\" data-end=\"4132\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4076\" data-end=\"4182\"\u003e\n\u003cstrong data-start=\"4108\" data-end=\"4132\"\u003eCircuit Requirement:\u003c\/strong\u003e 15A dedicated circuit\u003cbr data-start=\"4154\" data-end=\"4157\"\u003e\u003cstrong data-start=\"4157\" data-end=\"4174\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4076\" data-end=\"4182\"\u003e\n\u003cstrong data-start=\"4157\" data-end=\"4174\"\u003eCurrent Draw:\u003c\/strong\u003e 9.2 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4184\" data-end=\"4205\"\u003eAirflow \u0026amp; Ducting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4206\" data-end=\"4371\"\u003e\n\u003cstrong data-start=\"4206\" data-end=\"4227\"\u003eSupply Duct Size:\u003c\/strong\u003e 8\"\u003cbr data-start=\"4230\" data-end=\"4233\"\u003e\u003cstrong data-start=\"4233\" data-end=\"4254\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4206\" data-end=\"4371\"\u003e\n\u003cstrong data-start=\"4233\" data-end=\"4254\"\u003eReturn Duct Size:\u003c\/strong\u003e 8\"\u003cbr data-start=\"4257\" data-end=\"4260\"\u003e\u003cstrong data-start=\"4260\" data-end=\"4284\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4206\" data-end=\"4371\"\u003e\n\u003cstrong data-start=\"4260\" data-end=\"4284\"\u003eMaximum Duct Length:\u003c\/strong\u003e 25 ft per duct run\u003cbr data-start=\"4303\" data-end=\"4306\"\u003e\u003cstrong data-start=\"4306\" data-end=\"4328\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4206\" data-end=\"4371\"\u003e\n\u003cstrong data-start=\"4306\" data-end=\"4328\"\u003eAirflow – Speed 1:\u003c\/strong\u003e 360 CFM\u003cbr data-start=\"4336\" data-end=\"4339\"\u003e\u003cstrong data-start=\"4339\" data-end=\"4361\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4206\" data-end=\"4371\"\u003e\n\u003cstrong data-start=\"4339\" data-end=\"4361\"\u003eAirflow – Speed 2:\u003c\/strong\u003e 420 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4373\" data-end=\"4400\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4401\" data-end=\"4483\"\u003e\n\u003cstrong data-start=\"4401\" data-end=\"4428\"\u003eDimensions (L × W × D):\u003c\/strong\u003e 33.9\" × 13.8\" × 13.8\"\u003cbr data-start=\"4450\" data-end=\"4453\"\u003e\u003cstrong data-start=\"4453\" data-end=\"4464\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4401\" data-end=\"4483\"\u003e\n\u003cstrong data-start=\"4453\" data-end=\"4464\"\u003eWeight:\u003c\/strong\u003e 40 kg (88.2 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4485\" data-end=\"4507\"\u003eAdditional Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"4508\" data-end=\"4590\"\u003e\n\u003cstrong data-start=\"4508\" data-end=\"4524\"\u003eRefrigerant:\u003c\/strong\u003e R290 (eco-friendly refrigerant)\u003cbr data-start=\"4556\" data-end=\"4559\"\u003e\u003cstrong data-start=\"4559\" data-end=\"4580\"\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4508\" data-end=\"4590\"\u003e\n\u003cstrong data-start=\"4559\" data-end=\"4580\"\u003eDrain Connection:\u003c\/strong\u003e 5\/8\" ID\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"4592\" data-end=\"4604\"\u003eWarranty\u003c\/h3\u003e\n\u003cp data-start=\"4605\" data-end=\"4674\"\u003e\u003cstrong data-start=\"4605\" data-end=\"4618\"\u003eCoverage:\u003c\/strong\u003e 2-year manufacturer warranty covering parts and labor\u003c\/p\u003e\n\u003cp data-start=\"4676\" data-end=\"4795\"\u003e\u003cem data-start=\"4676\" data-end=\"4795\"\u003eActual performance depends on cellar insulation quality, construction, ambient conditions, and ducting configuration.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eManuals for APEX 5000 Wine Cellar Cooling Systems of Panthaire\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca title=\"Product Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/man.pdf?v=1767995987\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/tech_sheet.pdf?v=1767995985\" title=\"Technical Sheet\" target=\"_blank\"\u003eTechnical Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/user_guide_49f67c9b-0062-42c5-ac9e-010fa4a66a59.pdf?v=1767995981\" title=\"User Guide\" target=\"_blank\"\u003eUser Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/3318\/6660\/files\/aKUr1KTt2nPbaffx_ProductSheet5000-EN-v1.5.pdf?v=1768000460\" title=\"Product Sheet\" rel=\"noopener\" target=\"_blank\"\u003eProduct Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"4802\" data-end=\"4838\"\u003eInstallation Notes \u0026amp; Requirements\u003c\/h2\u003e\n\u003cp data-start=\"4840\" data-end=\"4948\"\u003eThe Pantheaire APEX 5000 requires \u003cstrong data-start=\"4874\" data-end=\"4903\"\u003eprofessional installation\u003c\/strong\u003e to ensure optimal performance and longevity.\u003c\/p\u003e\n\u003cp data-start=\"4950\" data-end=\"4967\"\u003eFor best results:\u003c\/p\u003e\n\u003cul data-start=\"4968\" data-end=\"5220\"\u003e\n\u003cli data-start=\"4968\" data-end=\"5025\"\u003eCellar walls should meet \u003cstrong data-start=\"4995\" data-end=\"5013\"\u003eR20 insulation\u003c\/strong\u003e standards\u003c\/li\u003e\n\u003cli data-start=\"5026\" data-end=\"5100\"\u003eInsulated ducting is required to prevent condensation and thermal loss\u003c\/li\u003e\n\u003cli data-start=\"5101\" data-end=\"5160\"\u003eAdequate clearance and airflow paths must be maintained\u003c\/li\u003e\n\u003cli data-start=\"5161\" data-end=\"5220\"\u003eDrainage must be properly routed for condensate removal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5222\" data-end=\"5294\"\u003eOur experts are available to help confirm system sizing before purchase.\u003c\/p\u003e\n\u003ch2 data-start=\"5301\" data-end=\"5329\"\u003eWarranty \u0026amp; Expert Support\u003c\/h2\u003e\n\u003cp data-start=\"5331\" data-end=\"5569\"\u003eThe APEX 5000 is backed by a \u003cstrong data-start=\"5360\" data-end=\"5395\"\u003e2-year parts and labor warranty\u003c\/strong\u003e and supported by \u003cstrong data-start=\"5413\" data-end=\"5451\"\u003eNorth American service technicians\u003c\/strong\u003e. Replacement parts and technical assistance are readily available to support your system throughout its service life.\u003c\/p\u003e\n\u003ch2 class=\"style-scope ytd-watch-metadata\"\u003eModern Wine Storage \u0026amp; Cooling Setup Walk‑Through Video\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/h5U3PxAB0nU?si=tBBG-u6sM8kX7YMd\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Panthaire","offers":[{"title":"Default Title","offer_id":49860896620790,"sku":"APEX 5000","price":6525.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/4106\/9046\/files\/panthaire-wine-cellar-cooling-systems-apex-5000-luxury-appliances-direct-1216258845.png?v=1768188368","url":"https:\/\/luxuryappliancesdirect.com\/products\/panthaire-wine-cellar-cooling-systems-apex-5000","provider":"Luxury Appliances Direct","version":"1.0","type":"link"}